Telephone
(562) 404-9955Best for anything where a drawing, a nameplate or a machine is in front of you and a sentence of description would take five minutes to type.
// Contact
The laboratory is at 13564 E. Imperial Hwy, Unit D, in Santa Fe Springs. Samples can be shipped or brought in by hand. Whichever you do, register the sample first so it is logged the moment it reaches the bench and you hold a record of what you sent.
01Reaching us
One telephone number, one email address, one street address. Which route you pick does not change how fast a useful answer comes back — what you put in front of us does, and the two sections after this one set out exactly what that is.
Best for anything where a drawing, a nameplate or a machine is in front of you and a sentence of description would take five minutes to type.
Best for anything with a reference number, a document, or a list of samples attached to it — and it leaves both of us with the thread afterwards.
If you are driving a sample over, call (562) 404-9955 before you set off, so somebody is expecting it and it is logged on arrival rather than riding around in a van for the rest of the afternoon.
02Getting the sample here
Both are normal. The difference is not the testing — it is who is responsible for the sample while it is in motion, and how much of the paperwork has to travel with it.
Chiller Services Refrigerants is a refrigerant reclaimer under common ownership with this laboratory, in the neighbouring unit. We say so wherever it comes up rather than hoping you do not notice the signage. How the two are kept apart.
03What to include
None of this is administrative box-ticking. Each line below changes what can physically be measured, or which limit the result is read against — a sample that arrives without them cannot be started, only queried.
| Include | Why it changes the result |
|---|---|
| The refrigerant designation | The limits are per refrigerant, not one generic column: the water limit alone takes 4 different values across the single-component table, and 6 of those fluids carry no non-condensables limit at all. All of them are published. |
| Which edition you are being judged against | 40 CFR 82 subpart F, Appendix A is the binding text for Section 608 work; AHRI 700-2019 and AHRI 700-2024 differ from it and from each other. Tell us which one the job answers to and we report against that one. |
| The source temperature when you drew the sample | The non-condensables limit is defined as % by volume @ 25.0 °C, so the temperature of the source at sampling time is part of the record, not a nicety. |
| A separate vapour-phase sample, where non-condensables apply | Non-condensables are the one vapor-phase characteristic; every other line is liquid phase. One liquid cylinder cannot answer both. If your fluid is exempt in the edition that applies, you need only the one. |
| The completed form from the kit, inside the box | It ties the cylinder to the system it came from. A cylinder that arrives with nothing written down is a cylinder we have to phone you about before anything can start. |
| Where the report goes, and any PO reference | One email address that will still exist in six months, plus whatever reference your accounts payable will want to see on the paperwork. |
Drawn from the Liquid valve · filled 75–80% · about 350 g · full procedure
| Include | Why it changes the result |
|---|---|
| The oil type | Condition and wear analysis for chiller and refrigeration compressor oil — mineral, alkylbenzene, POE and PVE. |
| The compressor and system it came from | Machine, refrigerant charge, and what prompted the sample — a routine interval, a suspected burnout, or a change of oil. Condition analysis is read against what the machine has been doing. |
| A degassed sample in the supplied bottle | Borosilicate graduated glass sample bottle, degassed before it is sealed. Dissolved refrigerant coming out of solution in transit changes what arrives. |
| Prompt despatch | POE and Solest oils absorb moisture quickly, even in a sealed bottle. Send samples promptly. |
Oil is a separate service and a separate sample. The AHRI Refrigerant Testing Laboratory certification covers refrigerant testing; it carries no oil scope, and we do not present it as though it does. The oil sampling procedure.
04Where to point a question
Both arrive at the same number and the same inbox. What differs is what you should have in front of you before you make contact.
A result we have already issued
The fastest route is a reply on the same email thread the report arrived on — it carries the reference and the attachment with it. Starting fresh instead? Quote three things:
If the query is that a value sits close to a limit, all 5decision rules were published before your sample was drawn — among them “A result equal to the limit passes” and “Non-condensables are not always required”. Read them before you call, and the conversation starts from the same page.
Where a result feeds what a reclaimer pays you — including our affiliate — the independence policy sets out how that is handled.
A new enquiry
Any of the routes below works. These four turn the first reply into an answer instead of a request for more information:
If you already know you want a test, skip the conversation entirely and register the sample — it asks for the same four things and puts a record in place at the same time.
05Write to us
For a sample you have decided to send, the registration form is the better door — it opens a record. This one is for everything before that decision.
Faster alternatives